Automatic Vehicle Classification for Toll Management System

It is usually used in vehicle inspection applications to start and stop transactions (for example, when toll stations pay). Transmitters and receivers are installed on both sides of the toll lane, and the radiographic grating is perpendicular to the lane.

Send InquiryChat Now
  • DETAILS
  • SEPCIFICATION
  • INSTALLATION
  • PARAMETER


  • Product Features

    1. Integrateddesign,no controller ,easyto use.

    2. Double NPN output:

    output 1: vehicle detection signal

    output 2: separetion light curtain breakdown alarm

    3. Enable to detect objects above 150mm only.

    4. 1 mm resolution ratio which can avoid the wrong movements caused by sunlight, mosquitoes and sludge caused errors.

    5. Examine the malfunction automatically and ignore the fault beams which can output the alarm signal while maintaining normal work.

    6. Using high energy and high penetration Phototube, easy to install and maintenance.

    7. Solid aluminum made special protective case make sure it can be used in bad environment.

    8. Applicable temperature:-10℃——55℃

    Ambient humidity:RH≤85%(20℃)

    11.Integration design, no controller, and simple to use

    12. Detection range: 0-5m/0-10m

    13. The special protective case made of the solid aluminum profile. It can assurance products can use in the rugged environment.

    14. stop transactions (for example, when toll stations pay). Transmitters and receivers are installed on both sides of the toll lane, and the radiographic grating is perpendicular to the lane.


    FAQ

    1. What will happen to glass at high temperature and low temperature?

    The temperature starts to heat below 0 degrees (can be set at the scene); the temperature is

    higher than 96 degrees and starts heating(can be set at the scene).


    2. When the vehicle separator temperature is too high, what are the protective measures?

    Overheat protection control: when the temperature is higher than 45 degrees, the heating is cut off.

    3. Where can the vehicle separator be used?

    Highway toll station, automatic vehicle classification system, parking lot, infrared scanning vehicle separator for charging management system, etc.


    4. How can I make a payment?

    We have 4 ways of payment:

    1) T/T  2) through Alibaba international station  3) L/C  4) WESTERN UNION  5) PAYPAL


    5. How many kinds of output are there?

    Double NPN output mode:

    Output mode 1: vehicle detection signal output

    Output mode 2: light screen fault alarm

     




  • Note: The quantity of beams is up to 72 beams.
    If you need the detection range of more than 5 meters, please contact customer service.


    10mm Beam Pitch
    Light BeamEffective Protection Height mm (H)Height of Light Curtain mm (L)Product ModelOutput of SignalDetection distance
    RS485NPNPNPNPNPNP
    870128QLV08/10-70RABCD0.3-5m
    1090148QLV10/10-90RABCD0.3-5m
    12110168QLV12/10-110RABCD0.3-5m
    14130188QLV14/10-130RABCD0.3-5m
    16150208QLV16/10-150RABCD0.3-5m
    18170228QLV18/10-170RABCD0.3-5m
    20190248QLV20/10-190RABCD0.3-5m
    22210268QLV22/10-210RABCD0.3-5m
    24230288QLV24/10-230RABCD0.3-5m
    26250308QLV26/10-250RABCD0.3-5m
    28270328QLV28/10-270RABCD0.3-5m
    30290348QLV30/10-290RABCD0.3-5m
    32310368QLV32/10-310RABCD0.3-5m
    34330390QLV34/10-330RABCD0.3-5m
    20mm Beam Pitch
    Light BeamEffective Protection Height mm (H)Height of Light Curtain mm (L)Product ModelOutput of SignalDetection distance
    RS485NPNPNPNPNPNP
    460125QLV04/20-60RABCD0.3-5m
    6100165QLV06/20-100RABCD0.3-5m
    8140205QLV08/20-140RABCD0.3-5m
    10180245QLV10/20-180RABCD0.3-5m
    12220285QLV12/20-220RABCD0.3-5m
    14260325QLV14/20-260RABCD0.3-5m
    16300365QLV16/20-300RABCD0.3-5m
    18340405QLV18/20-340RABCD0.3-5m
    20380445QLV20/20-380RABCD0.3-5m
    22420485QLV22/20-420RABCD0.3-5m
    24460525QLV24/20-460RABCD0.3-5m
    26500565QLV26/20-500RABCD0.3-5m
    28540605QLV28/20-540RABCD0.3-5m
    30580645QLV30/20-580RABCD0.3-5m
    32620685QLV32/20-620RABCD0.3-5m
    40mm Beam Pitch
    Light BeamEffective Protection Height mm (H)Height of Light Curtain mm (L)Product ModelOutput of SignalDetection distance
    RS485NPNPNPNPNPNP
    4120195QLV04/40-120RABCD0.3-5m
    6200275QLV06/40-200RABCD0.3-5m
    8280355QLV08/40-280RABCD0.3-5m
    10360435QLV10/40-360RABCD0.3-5m
    12440515QLV12/40-440RABCD0.3-5m
    14520595QLV14/40-520RABCD0.3-5m
    16600675QLV16/40-600RABCD0.3-5m
    18680755QLV18/40-680RABCD0.3-5m
    20760835QLV20/40-760RABCD0.3-5m
    22840915QLV22/40-840RABCD0.3-5m
    24920995QLV24/40-920RABCD0.3-5m
    2610001075QLV26/40-1000RABCD0.3-5m
    2810801155QLV28/40-1080RABCD0.3-5m
    3011601235QLV30/40-1160RABCD0.3-5m
    3212401315QLV32/40-1240RABCD0.3-5m
    80mm Beam Pitch
    Light BeamEffective Protection Height mm (H)Height of Light Curtain mm (L)Product ModelOutput of SignalDetection distance
    RS485NPNPNPNPNPNP
    4240375QLV04/80-240RABCD0.3-5m
    6400535QLV06/80-400RABCD0.3-5m
    8560695QLV08/80-560RABCD0.3-5m
    10720855QLV10/80-720RABCD0.3-5m
    128801015QLV12/80-880RABCD0.3-5m
    1410401175QLV14/80-1040RABCD0.3-5m
    1612001335QLV16/80-1200RABCD0.3-5m
    1813601495QLV18/80-1360RABCD0.3-5m
    2015201655QLV20/80-1520RABCD0.3-5m
    2216801815QLV22/80-1680RABCD0.3-5m
    2418401975QLV24/80-1840RABCD0.3-5m
    2620002135QLV26/80-2000RABCD0.3-5m
    2821602295QLV28/80-2160RABCD0.3-5m
    3023202455QLV30/80-2320RABCD0.3-5m








  • TECHNICAL PARAMETER

    Heating Power Supply

    24v 10A

    Height of Light Curtain

    50mm-2840mm

    Main Thermostat

    Disk Encapsulation

    Closed temperature: 4 ℃ Disconnection temperature: 29 ℃

    Standby Thermostat

    Closed temperature: 55 ℃ Disconnection temperature: 36 ℃

    Beam Pitch

    10/14/20/25/30/40/80mm (customizable)

    Humidity Switch

    Mechanical   nylon membrane trigger switch

    Relative   Humidity: 20-80%

    Indication Light

    The front red LED lamp shines when   the heating element turns on

    Structure

    Shell: stainless steel or aluminium alloy, window: heating glass

    Working Temperature

    Operating:-20~+70℃(do not freeze),

    Protection Level

    NEMA 3R (IEC IP54)


Hot Tags: automatic vehicle classification for toll management system, China, suppliers, manufacturers, factory, buy, price, made in China