Product SpecificationsDK-GF18-50NO-ZAA
ModelDK-GF18-50NO-ZAA
Sensing modeDiffuse reflection
Sensing distance30-500 mm adjustable
Light source850 nm infrared
Operating voltage10-30 V DC
OutputNPN NO, DC 3-wire
Protection levelIP55
Housing50 x 50 x 18 mm, ABS
Response time5 ms
Switching frequency100 Hz
ConnectionØ6.5 mm 2 m PVC cable
WeightAbout 93 g
CertificationCE, RoHS
Detail Information

DADISICK · DK-GF18 Series

DK-GF18-50NO-ZAA Diffuse Reflection Photoelectric Sensor

DC 3-wire diffuse reflection sensor with an adjustable 30-500 mm sensing distance and an NPN normally-open output. Part of the DK-GF18 square sensor series in a 50 x 50 x 18 mm ABS housing.

  • 30-500 mm adjustable
  • 10-30 V DC
  • NPN NO
  • IP55
  • CE
  • RoHS
Get a Quote
DK-GF18-50NO-ZAA diffuse reflection photoelectric sensor with bracket
DK-GF18 square housing with red LED indication and 2 m PVC cable.

Technical parameters

ParameterValue
Sensing distance30-500 mm, adjustable
Light source850 nm infrared light
No-load current≤30 mA
Protection levelIP55
Connection methodØ6.5 mm 2 m PVC cable, 3x0.33 mm² / 4x0.33 mm²
WeightAbout 93 g
Operating voltage10-30 V DC
Output typeDC 3-wire NPN NO
Maximum load current150 mA
Voltage drop<1.5 V
Leakage current<0.01 mA
Switching frequency100 Hz
Response time5 ms
Short-circuit protectionYes
Overload protection point300 mA
Switching hysteresis<15% (Sr)
Repeat accuracy<5% (Sr)
Working temperature0 °C to +55 °C
Standard detection object200 x 200 mm white cardboard
Housing50 x 50 x 18 mm, ABS
IndicatorRed LED
CertificationCE, RoHS

All values are taken from the DK-GF18 technical data sheet, revision dated 2026-04-20. Dimensions are for reference only; please refer to the actual measurement.

Dimensions

DK-GF18 DC version dimension drawing 50 mm x 50 mm x 18 mm
DC version outline: 50 x 50 mm face, 33 mm body depth, 18 mm thickness, Ø5 mm cable entry.
DK-GF18 sensor with 2 m PVC cable and reflective board
Sensor with 2 m PVC cable; a reflective board is supplied with retro-reflective versions.

Wiring

DC 3-wire NPN NO wiring diagram for DK-GF18-50NO-ZAA
DC 3-wire NPN NO connection. Brown to +10-30 V DC, Blue to 0 V, Black to the load.
Wire colourFunction
Brown (1)+10-30 V DC
Blue (3)0 V
Black (2)Switched output to load (NO)

Confirm the wiring against the label of the unit received before energising. Do not connect the output to a load exceeding the rated current.

Request a quotation for DK-GF18-50NO-ZAA

Tell us the target object, sensing distance, supply voltage and quantity. Our engineers will confirm the exact part number and send you a quotation. This model is a general-purpose photoelectric sensor for object detection; it is not a safety-rated device and must not be used for personnel protection.

Get a Quote
Review
  • 加载中···

Let us know how we can help you by completing the form below.

Thank you for your inquiry. We will provide you with professional advice and comprehensive support and services throughout the entire life cycle of your sensor or safety system.
*Email
Name
*Title
*Content
Upload
  • Only supports .rar/.zip/.jpg/.png/.gif/.doc/.xls/.pdf, maximum 20MB.
Thank you for sharing this information. Our dealer management team will contact you to discuss further cooperation. Please be assured that your inquiry is important to us and we take your privacy seriously.
Get Your Free Automated Safety Sensor Solution